Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38448258

RESUMO

BACKGROUND: Left atrial appendage (LAA) occluder embolization is an infrequent but serious complication. OBJECTIVES: We aim to describe timing, management and clinical outcomes of device embolization in a multi-center registry. METHODS: Patient characteristics, imaging findings and procedure and follow-up data were collected retrospectively. Device embolizations were categorized according to 1) timing 2) management and 3) clinical outcomes. RESULTS: Sixty-seven centers contributed data. Device embolization occurred in 108 patients. In 70.4 % of cases, it happened within the first 24 h of the procedure. The device was purposefully left in the LA and the aorta in two (1.9 %) patients, an initial percutaneous retrieval was attempted in 81 (75.0 %) and surgery without prior percutaneous retrieval attempt was performed in 23 (21.3 %) patients. Two patients died before a retrieval attempt could be made. In 28/81 (34.6 %) patients with an initial percutaneous retrieval attempt a second, additional attempt was performed, which was associated with a high mortality (death in patients with one attempt: 2.9 % vs. second attempt: 21.4 %, p < 0.001). The primary outcome (bailout surgery, cardiogenic shock, stroke, TIA, and/or death) occurred in 47 (43.5 %) patients. Other major complications related to device embolization occurred in 21 (19.4 %) patients. CONCLUSIONS: The majority of device embolizations after LAA closure occurs early. A percutaneous approach is often the preferred method for a first rescue attempt. Major adverse event rates, including death, are high particularly if the first retrieval attempt was unsuccessful. CONDENSED ABSTRACT: This dedicated multicenter registry examined timing, management, and clinical outcome of device embolization. Early embolization (70.4 %) was most frequent. As a first rescue attempt, percutaneous retrieval was preferred in 75.0 %, followed by surgical removal (21.3 %). In patients with a second retrieval attempt a higher mortality (death first attempt: 2.9 % vs. death second attempt: 24.1 %, p < 0.001) was observed. Mortality (10.2 %) and the major complication rate after device embolization were high.

4.
AsiaIntervention ; 9(1): 70-77, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36936101

RESUMO

Percutaneous left atrial appendage closure (LAAC) has proven to be an effective alternative to oral anticoagulation (OAC) for stroke prevention in patients with non-valvular atrial fibrillation (NVAF). International guidelines traditionally recommend LAAC for NVAF patients at high thromboembolic risk and contraindication to or at high risk for OAC. However, there are many other clinical situations in which this procedure may also be beneficial. This paper discusses the potential role of LAAC in specific haemorrhagic diseases (cerebral amyloid angiopathy, age-related macular degeneration, hereditary haemorrhagic telangiectasia, and Moyamoya disease), after left atrial appendage (LAA) electrical isolation, in cases of persistent thrombus inside the LAA, in end-stage renal disease and in special groups of patients for whom low compliance and persistence to OAC may be anticipated.

5.
Arq Bras Cardiol ; 119(1): 48-56, 2022 07.
Artigo em Inglês, Português | MEDLINE | ID: mdl-35544849

RESUMO

BACKGROUND: Left atrial appendage (LAA) closure has been an alternative to oral anticoagulation (OAC) for stroke prevention in patients with non-valvular atrial fibrillation (NVAF). OBJECTIVES: To report the first results of an initial multicenter experience in Brazil and to investigate the feasibility, safety, and efficacy of LAA closure with the new LAmbre device. METHODS: We collected procedural and follow-up data of 51 consecutive patients with non-valvular atrial fibrillation, restrictions for long-term OAC and suitable anatomy that underwent LAA closure with the LAmbre device in 18 centers in Brazil. Procedural indications were significant bleeding under OAC (47.1%), stroke or persistent LAA thrombus despite OAC (27.5%), bleeding plus stroke (17.6%), other clinical contraindications for OAC (5.9%), and patient's choice due to sports practice (1.9%). RESULTS: Twenty-five men (49%) and 26 women (51%), with a mean age of 76±7.7 years, mean CHA2DS2-VASc score of 4.6± 1.7 and mean HAS-BLED score of 3.4± 1.1 were studied. Procedural success rate was 100%. Procedure-related immediate complications were pericardial effusion in two patients, and immediate device embolization in one case. No large residual shunts (> 5 mm) were observed, and small shunts (<5mm) were detected in four patients by color Doppler at the end of the procedure. After a mean follow-up of 18 ± 12 months, there were no deaths, strokes nor any other major complications. CONCLUSION: LAA occlusion with the LAmbre device was safe and effective in this small case series. Despite these encouraging initial results, the small number of cases warrants further studies with longer-term follow-up.


FUNDAMENTO: A oclusão do apêndice atrial esquerdo (AAE) tem se mostrado uma alternativa à terapia de anticoagulação oral (ACO) para prevenção de acidente vascular cerebral (AVC) em pacientes com fibrilação atrial não valvar (FANV). OBJETIVOS: Descrever os primeiros resultados de uma experiência inicial multicêntrica no Brasil e investigar a viabilidade, a segurança e a eficácia da oclusão do AAE com o novo dispositivo LAmbre. MÉTODOS: Coletamos dados do procedimento e do acompanhamento de 51 pacientes consecutivos com FANV, restrições para ACO em longo prazo e com anatomia adequada, submetidos à oclusão do AAE com o dispositivo LAmbre em 18 centros no Brasil. Indicações para o procedimento foram: sangramento importante em pacientes recebendo ACO (47,1%), AVC ou trombo persistente no AAE apesar de ACO adequada (27.5%), sangramento e AVC (17.6%), outras contraindicações clínicas apara ACO (5,9%), e escolha do paciente devido à prática esportiva (1,9%). RESULTADOS: Foram estudados 25 homens (49%) e 26 mulheres (51%), com idade média de 76±7,7 anos, escore CHA2DS2-VASc médio de 4,6± 1,7 e escore HAS-BLED médio de 3.4± 1,1. A taxa de sucesso do procedimento foi de 100%. As complicações imediatas relacionadas ao procedimento foram derrame pericárdico em dois pacientes, e embolização do dispositivo em um caso. Não foram observados shunts residuais > 5mm. Shunts < 5mm foram detectados em quatro pacientes por Doppler colorido ao final do procedimento. Após um período médio de acompanhamento de 18 meses ± 12 meses, não foram observados óbito, AVC ou complicações maiores. CONCLUSÃO: A oclusão do AAE com o dispositivo LAmbre foi segura e eficaz nesta pequena série de casos. Apesar desses resultados iniciais encorajadores, dado o pequeno número de casos, serão necessários mais estudos com um maior período de acompanhamento.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Brasil , Cateterismo Cardíaco/métodos , Feminino , Humanos , Masculino , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
6.
Arq. bras. cardiol ; 119(1): 48-56, abr. 2022. tab, graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1383717

RESUMO

Resumo Fundamento A oclusão do apêndice atrial esquerdo (AAE) tem se mostrado uma alternativa à terapia de anticoagulação oral (ACO) para prevenção de acidente vascular cerebral (AVC) em pacientes com fibrilação atrial não valvar (FANV). Objetivos Descrever os primeiros resultados de uma experiência inicial multicêntrica no Brasil e investigar a viabilidade, a segurança e a eficácia da oclusão do AAE com o novo dispositivo LAmbre. Métodos Coletamos dados do procedimento e do acompanhamento de 51 pacientes consecutivos com FANV, restrições para ACO em longo prazo e com anatomia adequada, submetidos à oclusão do AAE com o dispositivo LAmbre em 18 centros no Brasil. Indicações para o procedimento foram: sangramento importante em pacientes recebendo ACO (47,1%), AVC ou trombo persistente no AAE apesar de ACO adequada (27.5%), sangramento e AVC (17.6%), outras contraindicações clínicas apara ACO (5,9%), e escolha do paciente devido à prática esportiva (1,9%). Resultados Foram estudados 25 homens (49%) e 26 mulheres (51%), com idade média de 76±7,7 anos, escore CHA2DS2-VASc médio de 4,6± 1,7 e escore HAS-BLED médio de 3.4± 1,1. A taxa de sucesso do procedimento foi de 100%. As complicações imediatas relacionadas ao procedimento foram derrame pericárdico em dois pacientes, e embolização do dispositivo em um caso. Não foram observados shunts residuais > 5mm. Shunts < 5mm foram detectados em quatro pacientes por Doppler colorido ao final do procedimento. Após um período médio de acompanhamento de 18 meses ± 12 meses, não foram observados óbito, AVC ou complicações maiores. Conclusão A oclusão do AAE com o dispositivo LAmbre foi segura e eficaz nesta pequena série de casos. Apesar desses resultados iniciais encorajadores, dado o pequeno número de casos, serão necessários mais estudos com um maior período de acompanhamento.


Abstract Background Left atrial appendage (LAA) closure has been an alternative to oral anticoagulation (OAC) for stroke prevention in patients with non-valvular atrial fibrillation (NVAF). Objectives To report the first results of an initial multicenter experience in Brazil and to investigate the feasibility, safety, and efficacy of LAA closure with the new LAmbre device. Methods We collected procedural and follow-up data of 51 consecutive patients with non-valvular atrial fibrillation, restrictions for long-term OAC and suitable anatomy that underwent LAA closure with the LAmbre device in 18 centers in Brazil. Procedural indications were significant bleeding under OAC (47.1%), stroke or persistent LAA thrombus despite OAC (27.5%), bleeding plus stroke (17.6%), other clinical contraindications for OAC (5.9%), and patient's choice due to sports practice (1.9%). Results Twenty-five men (49%) and 26 women (51%), with a mean age of 76±7.7 years, mean CHA2DS2-VASc score of 4.6± 1.7 and mean HAS-BLED score of 3.4± 1.1 were studied. Procedural success rate was 100%. Procedure-related immediate complications were pericardial effusion in two patients, and immediate device embolization in one case. No large residual shunts (> 5 mm) were observed, and small shunts (<5mm) were detected in four patients by color Doppler at the end of the procedure. After a mean follow-up of 18 ± 12 months, there were no deaths, strokes nor any other major complications. Conclusion LAA occlusion with the LAmbre device was safe and effective in this small case series. Despite these encouraging initial results, the small number of cases warrants further studies with longer-term follow-up.

7.
Arq Bras Cardiol ; 116(6): 1059-1069, 2021 06.
Artigo em Inglês, Português | MEDLINE | ID: mdl-34133587

RESUMO

BACKGROUND: Mitral regurgitation (MR) is prevalent in patients undergoing transcatheter aortic valve implantation (TAVI). There are some controversies about the prognostic impact of MR in survival of TAVI patients. OBJECTIVE: To examine the relationship between TAVI and MR in a patient population from the Brazilian TAVI Registry. METHODS: Seven hundred and ninety-five patients from the Brazilian TAVI Registry were divided at baseline, discharge, and follow-up according to their MR grade as follows: absent/mild (AMMR) or moderate/severe (MSMR). They were subsequently regrouped according to their immediate and late changes in MR severity after TAVI as follows: no change, improved, or worsened MR. Predictors and prognostic impact on baseline as well as changes in MR severity were analyzed. Statistical significance was set at p < 0.05. RESULTS: Baseline MSMR was present in 19.3% of patients and was a predictor of increased late mortality. Immediately after TAVI, 47.4 % of cases improved to AMMR, predicted by a higher Society of Thoracic Surgeons score and a higher grade of baseline aortic regurgitation. Upon follow-up, 9.2% of cases of AMMR worsened to MSMR, whereas 36.8% of cases of MSMR improved to AMMR. Lower baseline left ventricular ejection fraction (LVEF) and improvement in LVEF at follow-up were predictors of MR improvement. Progressive worsening of MR upon follow-up was an independent predictor of higher late mortality after TAVI (p = 0.005). CONCLUSIONS: Baseline MSMR predicts late mortality after TAVI. Lower LVEF and improved LVEF at follow-up predict MR improvement after TAVI. Progressive worsening of MR severity at follow-up is an independent predictor of late mortality, which is a rare finding in the literature.


FUNDAMENTO: A regurgitação mitral (RM) é prevalente em pacientes submetidos a implante transcateter de válvula aórtica (TAVI). Há algumas controvérsias sobre o impacto prognóstico da RM na sobrevida de pacientes submetidos a TAVI. OBJETIVO: Examinar a relação entre TAVI e RM em uma população de pacientes do Registro Brasileiro de TAVI. MÉTODOS: Setecentos e noventa e cinco pacientes do Registro Brasileiro de TAVI foram divididos na linha de base, alta e acompanhamento de acordo com o grau da RM da maneira seguinte: ausente/leve (RMAL) ou moderado/grave (RMMG). Eles foram subsequentemente reagrupados de acordo com as mudanças imediatas e tardias na gravidade da RM após TAVI da maneira seguinte: RM sem mudança, melhora ou piora. Foram analisados os preditores e o impacto prognóstico na linha de base, bem como as mudanças na gravidade da RM. A significância estatística foi estabelecida em p < 0,05. RESULTADOS: RMMG basal estava presente em 19,3% dos pacientes e foi um preditor de aumento da mortalidade tardia. Imediatamente após o TAVI, 47,4% dos casos melhoraram para RMAL, previsto por uma pontuação mais alta da Society of Thoracic Surgeons e um grau mais alto de regurgitação aórtica basal. No acompanhamento, 9,2% dos casos de RMAL pioraram para RMMG, enquanto 36,8% dos casos de RMMG melhoraram para RMAL. Fração de ejeção do ventrículo esquerdo (FEVE) mais baixa na linha de base e melhora na FEVE durante o acompanhamento foram preditores de melhora da RM. Piora progressiva da RM no acompanhamento foi um preditor independente de maior mortalidade tardia após TAVI (p = 0,005). CONCLUSÕES: A RMMG na linha de base é um preditor de mortalidade tardia após TAVI. FEVE mais baixa e melhora na FEVE durante o acompanhamento são preditores de melhora da RM após TAVI. A pior progressiva da gravidade da RM durante o acompanhamento é um preditor independente de mortalidade tardia; isto é um achado raro na literatura.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Brasil , Seguimentos , Humanos , Insuficiência da Valva Mitral/cirurgia , Índice de Gravidade de Doença , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
8.
Arq. bras. cardiol ; 116(6): 1059-1069, Jun. 2021. tab, graf
Artigo em Inglês, Português | LILACS | ID: biblio-1278328

RESUMO

Resumo Fundamento A regurgitação mitral (RM) é prevalente em pacientes submetidos a implante transcateter de válvula aórtica (TAVI). Há algumas controvérsias sobre o impacto prognóstico da RM na sobrevida de pacientes submetidos a TAVI. Objetivo Examinar a relação entre TAVI e RM em uma população de pacientes do Registro Brasileiro de TAVI. Métodos Setecentos e noventa e cinco pacientes do Registro Brasileiro de TAVI foram divididos na linha de base, alta e acompanhamento de acordo com o grau da RM da maneira seguinte: ausente/leve (RMAL) ou moderado/grave (RMMG). Eles foram subsequentemente reagrupados de acordo com as mudanças imediatas e tardias na gravidade da RM após TAVI da maneira seguinte: RM sem mudança, melhora ou piora. Foram analisados os preditores e o impacto prognóstico na linha de base, bem como as mudanças na gravidade da RM. A significância estatística foi estabelecida em p < 0,05. Resultados RMMG basal estava presente em 19,3% dos pacientes e foi um preditor de aumento da mortalidade tardia. Imediatamente após o TAVI, 47,4% dos casos melhoraram para RMAL, previsto por uma pontuação mais alta da Society of Thoracic Surgeons e um grau mais alto de regurgitação aórtica basal. No acompanhamento, 9,2% dos casos de RMAL pioraram para RMMG, enquanto 36,8% dos casos de RMMG melhoraram para RMAL. Fração de ejeção do ventrículo esquerdo (FEVE) mais baixa na linha de base e melhora na FEVE durante o acompanhamento foram preditores de melhora da RM. Piora progressiva da RM no acompanhamento foi um preditor independente de maior mortalidade tardia após TAVI (p = 0,005). Conclusões A RMMG na linha de base é um preditor de mortalidade tardia após TAVI. FEVE mais baixa e melhora na FEVE durante o acompanhamento são preditores de melhora da RM após TAVI. A pior progressiva da gravidade da RM durante o acompanhamento é um preditor independente de mortalidade tardia; isto é um achado raro na literatura.


Abstract Background Mitral regurgitation (MR) is prevalent in patients undergoing transcatheter aortic valve implantation (TAVI). There are some controversies about the prognostic impact of MR in survival of TAVI patients. Objective To examine the relationship between TAVI and MR in a patient population from the Brazilian TAVI Registry. Methods Seven hundred and ninety-five patients from the Brazilian TAVI Registry were divided at baseline, discharge, and follow-up according to their MR grade as follows: absent/mild (AMMR) or moderate/severe (MSMR). They were subsequently regrouped according to their immediate and late changes in MR severity after TAVI as follows: no change, improved, or worsened MR. Predictors and prognostic impact on baseline as well as changes in MR severity were analyzed. Statistical significance was set at p < 0.05. Results Baseline MSMR was present in 19.3% of patients and was a predictor of increased late mortality. Immediately after TAVI, 47.4 % of cases improved to AMMR, predicted by a higher Society of Thoracic Surgeons score and a higher grade of baseline aortic regurgitation. Upon follow-up, 9.2% of cases of AMMR worsened to MSMR, whereas 36.8% of cases of MSMR improved to AMMR. Lower baseline left ventricular ejection fraction (LVEF) and improvement in LVEF at follow-up were predictors of MR improvement. Progressive worsening of MR upon follow-up was an independent predictor of higher late mortality after TAVI (p = 0.005). Conclusions Baseline MSMR predicts late mortality after TAVI. Lower LVEF and improved LVEF at follow-up predict MR improvement after TAVI. Progressive worsening of MR severity at follow-up is an independent predictor of late mortality, which is a rare finding in the literature.


Assuntos
Humanos , Estenose da Valva Aórtica/cirurgia , Implantação de Prótese , Substituição da Valva Aórtica Transcateter , Insuficiência da Valva Mitral/cirurgia , Valva Aórtica/cirurgia , Volume Sistólico , Índice de Gravidade de Doença , Brasil , Seguimentos , Função Ventricular Esquerda , Resultado do Tratamento
9.
Catheter Cardiovasc Interv ; 95(7): 1277-1284, 2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-32105408

RESUMO

AIMS: Peripheral arteries are constantly exposed to deformation (elongation, twisting, shortening, compression) making bioresorbable scaffolds (BRS) a potentially attractive therapeutic alternative to metallic stents. We conducted a long-term pilot preclinical study of a novel sirolimus-eluting BRS in peripheral arteries. METHODS AND RESULTS: Fourteen BRS were deployed in iliofemoral arteries of seven healthy Yucatan miniswine and examined with imaging, pharmacokinetic, histopathologic, and polymer degradation techniques at 0, 30, 90, 180 days, 1, 2, and 3.3 years. Angiographic late luminal loss remained unchanged at 30 and 180 days but significantly decreased from 1 to 3.3 years. optical coherence tomography (OCT) showed late increase in lumen area (1 year: 14.70 ± 3.58 mm2 , 2 years 22.04 ± 3.81 mm2 , and 3.3 years 23.45 ± 7.07 mm2 ; p < .05) primarily due to scaffold area enlargement between 1 and 3.3 years, while there was no difference in the percent area stenosis at all time points. Histologic evidence of scaffold degradation was observed starting at 2 years, with minimal inflammatory reaction. At 3.3 years, BRS struts were rarely discernible by OCT, confirmed by a nearly complete polymer degradation by molecular weight analysis. CONCLUSIONS: In this pilot study, novel sirolimus-eluting BRS showed promising acute and chronic performance in the iliofemoral arteries of Yucatan miniswine.


Assuntos
Implantes Absorvíveis , Angioplastia com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Artéria Femoral/efeitos dos fármacos , Artéria Ilíaca/efeitos dos fármacos , Sirolimo/administração & dosagem , Angioplastia com Balão/efeitos adversos , Animais , Fármacos Cardiovasculares/farmacocinética , Desenho de Equipamento , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/patologia , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/patologia , Teste de Materiais , Modelos Animais , Projetos Piloto , Sirolimo/farmacocinética , Suínos , Porco Miniatura , Fatores de Tempo
12.
Sleep Med X ; 2: 100012, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33870169

RESUMO

Ondine's curse is one of the most enchanting mythical tales in the field of Medicine. The nymph Ondine was an immortal water spirit who became human after falling in love for a man, marrying him, and having a baby. In one of the versions of the tale, when she caught her husband sleeping with another woman, she cursed him to remain awake in order to control his own breathing. During the 19th century, the rare syndrome characterized by loss of autonomic breath control, while voluntary respiration remains intact, was cleverly named "Ondine's curse". Nowadays, the term Ondine's curse is usually associated with congenital central hypoventilation syndrome; however, in medical literature, it also designates several respiratory disorders. Here, we present a review of the myth focused on history, arts and medicine.

14.
J Interv Cardiol ; 31(4): 450-454, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29356080

RESUMO

OBJECTIVES: To evaluate the systematic chain of care for patients with acute ST-elevation myocardial infarction (STEMI) referred for primary angioplasty in a capital city in Midwestern Brazil. BACKGROUND: Acute myocardial infarction is recognized as an important cause of morbidity and mortality and as a public health problem worldwide. Early specialized care is crucial for a good prognosis. METHODS: All STEMI patients receiving care through the public health system at two tertiary care centers from March 2012 to June 2014 were retrospectively analyzed. Symptom onset-to-balloon time and door-to-balloon time were analyzed and compared with current guideline recommendations. RESULTS: A total of 835 patients were included. Median symptom onset-to-balloon time was 32 h. A total of 783 (94%) patients had had symptoms for more than 12 h and 507 (61%) for more than 24 h. Only 51 (6%) patients arrived within 12 h of symptom onset and were treated with primary angioplasty. Among these patients, median door-to-balloon time was 37 min, in accordance with guideline recommendations. CONCLUSION: Treatment of STEMI through the public health system in a capital city in Midwestern Brazil falls short of the recommended guidelines due to failure in the initial links of the chain of care. This potentially reversible failure has an important impact on patient outcomes and on health care burden.


Assuntos
Angioplastia Coronária com Balão , Necessidades e Demandas de Serviços de Saúde , Infarto do Miocárdio com Supradesnível do Segmento ST , Tempo para o Tratamento , Idoso , Angioplastia Coronária com Balão/métodos , Angioplastia Coronária com Balão/estatística & dados numéricos , Brasil/epidemiologia , Feminino , Fidelidade a Diretrizes , Humanos , Masculino , Pessoa de Meia-Idade , Reperfusão Miocárdica/métodos , Reperfusão Miocárdica/estatística & dados numéricos , Guias de Prática Clínica como Assunto , Prognóstico , Estudos Retrospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/epidemiologia , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Tempo para o Tratamento/normas , Tempo para o Tratamento/estatística & dados numéricos
15.
Arq. bras. cardiol ; 109(6): 550-559, Dec. 2017. tab, graf
Artigo em Inglês | LILACS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-887985

RESUMO

Abstract Background: Transcatheter aortic valve implantation (TAVI) is a well-established procedure; however, atrioventricular block requiring permanent pacemaker implantation (PPI) is a common complication. Objectives: To determine the incidence, predictors and clinical outcomes of PPI after TAVI, focusing on how PPI affects left ventricular ejection fraction (LVEF) after TAVI. Methods: The Brazilian Multicenter TAVI Registry included 819 patients submitted to TAVI due to severe aortic stenosis from 22 centers from January/2008 to January/2015. After exclusions, the predictors of PPI were assessed in 670 patients by use of multivariate regression. Analysis of the ROC curve was used to measure the ability of the predictors; p < 0.05 was the significance level adopted. Results: Within 30 days from TAVI, 135 patients (20.1%) required PPI. Those patients were older (82.5 vs. 81.1 years; p = 0.047) and mainly of the male sex (59.3% vs 45%; p = 0.003). Hospital length of stay was longer in patients submitted to PPI (mean = 15.7 ± 25.7 vs. 11.8 ± 22.9 days; p < 0.001), but PPI affected neither all-cause death (26.7% vs. 25.6%; p = 0.80) nor cardiovascular death (14.1% vs. 14.8%; p = 0.84). By use of multivariate analysis, the previous presence of right bundle-branch block (RBBB) (OR, 6.19; 3.56-10.75; p ≤ 0.001), the use of CoreValve® prosthesis (OR, 3.16; 1.74-5.72; p ≤ 0.001) and baseline transaortic gradient > 50 mm Hg (OR, 1.86; 1.08-3.2; p = 0.025) were predictors of PPI. The estimated risk of PPI ranged from 4%, when none of those predictors was present, to 63%, in the presence of all of them. The model showed good ability to predict the need for PPI: 0.69 (95%CI: 0.64 - 0.74) in the ROC curve. The substudy of 287 echocardiograms during the 1-year follow-up showed worse LVEF course in patients submitted to PPI (p = 0.01). Conclusion: BRD prévio, gradiente aórtico médio > 50 mmHg e CoreValve® são preditores independentes de implante de MPD pós-TAVI. Ocorreu implante de MPD em aproximadamente 20% dos casos de TAVI, o que prolongou a internação hospitalar, mas não afetou a mortalidade. O implante de MPD afetou negativamente a FEVE pós-TAVI.


Resumo Fundamento: O implante valvar aórtico transcateter (TAVI) está bem estabelecido, porém, o bloqueio atrioventricular, com necessidade de marca-passo definitivo (MPD), é complicação frequente. Objetivo: Determinar a incidência, preditores e desfechos clínicos de implante de MPD após TAVI, focando em como a evolução da fração de ejeção do ventrículo esquerdo (FEVE), após o TAVI, é afetada pelo MPD. Métodos: No registro brasileiro foram incluídos 819 pacientes submetidos a TAVI por estenose aórtica severa em 22 centros entre janeiro/2008 e janeiro/2015. Após exclusões, os preditores de implante de MPD foram avaliados em 670 pacientes por regressão multivariada. Análise da curva ROC foi utilizada para medir a habilidade dos preditores; p < 0,05 foi considerado significativo. Resultados: Aos 30 dias, 135 pacientes (20,1%) necessitaram de MPD. Tais pacientes eram mais velhos (82,5 vs. 81,1 anos; p = 0,047) e predominantemente homens (59,3% vs 45%; p = 0,003). A permanência hospitalar foi maior no Grupo MPD (média= 15,7 ± 25,7 vs. 11,8 ± 22,9 dias; p < 0,001), mas o implante não afetou morte por qualquer causa (26,7% vs. 25,6%; p = 0,80) nem morte cardiovascular (14,1% vs. 14,8%; p = 0,84). Por análise multivariada, a presença prévia de bloqueio de ramo direito (BRD) (OR, 6,19; 3,56-10,75; p ≤ 0,001), o uso da prótese CoreValve® (OR, 3,16; 1,74-5,72; p ≤ 0,001) e gradiente transaórtico basal > 50 mmHg (OR, 1,86; 1,08-3,2; p= 0,025) foram preditores de implante de MPD. O risco estimado de implante de MPD foi 4%, quando nenhum dos fatores de risco estava presente, e 63% na presença de todos. O modelo mostrou boa habilidade de prever a necessidade de MPD: 0,69 (IC95%: 0,64 - 0,74) na curva ROC. Subestudo de 287 ecocardiogramas durante o seguimento de 1 ano mostrou pior evolução da FEVE no Grupo MPD (p = 0,01). Conclusão: Em crianças de 6 a 11 anos, circunferência da cintura aumentada está associada à PA elevada, mesmo quando o IMC é normal. (Arq Bras Cardiol. 2017; [online].ahead print, PP.0-0)


Assuntos
Humanos , Masculino , Feminino , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Marca-Passo Artificial/efeitos adversos , Bloqueio de Ramo/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Bloqueio Atrioventricular/cirurgia , Estenose da Valva Aórtica/cirurgia , Complicações Pós-Operatórias , Brasil , Fatores de Risco , Eletrocardiografia , Bloqueio Atrioventricular/fisiopatologia
16.
Arq Bras Cardiol ; 109(6): 550-559, 2017 Dec.
Artigo em Inglês, Português | MEDLINE | ID: mdl-29185614

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is a well-established procedure; however, atrioventricular block requiring permanent pacemaker implantation (PPI) is a common complication. OBJECTIVES: To determine the incidence, predictors and clinical outcomes of PPI after TAVI, focusing on how PPI affects left ventricular ejection fraction (LVEF) after TAVI. METHODS: The Brazilian Multicenter TAVI Registry included 819 patients submitted to TAVI due to severe aortic stenosis from 22 centers from January/2008 to January/2015. After exclusions, the predictors of PPI were assessed in 670 patients by use of multivariate regression. Analysis of the ROC curve was used to measure the ability of the predictors; p < 0.05 was the significance level adopted. RESULTS: Within 30 days from TAVI, 135 patients (20.1%) required PPI. Those patients were older (82.5 vs. 81.1 years; p = 0.047) and mainly of the male sex (59.3% vs 45%; p = 0.003). Hospital length of stay was longer in patients submitted to PPI (mean = 15.7 ± 25.7 vs. 11.8 ± 22.9 days; p < 0.001), but PPI affected neither all-cause death (26.7% vs. 25.6%; p = 0.80) nor cardiovascular death (14.1% vs. 14.8%; p = 0.84). By use of multivariate analysis, the previous presence of right bundle-branch block (RBBB) (OR, 6.19; 3.56-10.75; p ≤ 0.001), the use of CoreValve® prosthesis (OR, 3.16; 1.74-5.72; p ≤ 0.001) and baseline transaortic gradient > 50 mm Hg (OR, 1.86; 1.08-3.2; p = 0.025) were predictors of PPI. The estimated risk of PPI ranged from 4%, when none of those predictors was present, to 63%, in the presence of all of them. The model showed good ability to predict the need for PPI: 0.69 (95%CI: 0.64 - 0.74) in the ROC curve. The substudy of 287 echocardiograms during the 1-year follow-up showed worse LVEF course in patients submitted to PPI (p = 0.01). CONCLUSION: BRD prévio, gradiente aórtico médio > 50 mmHg e CoreValve® são preditores independentes de implante de MPD pós-TAVI. Ocorreu implante de MPD em aproximadamente 20% dos casos de TAVI, o que prolongou a internação hospitalar, mas não afetou a mortalidade. O implante de MPD afetou negativamente a FEVE pós-TAVI.


Assuntos
Valva Aórtica/cirurgia , Bloqueio Atrioventricular/cirurgia , Bloqueio de Ramo/cirurgia , Estimulação Cardíaca Artificial/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Bloqueio Atrioventricular/fisiopatologia , Brasil , Eletrocardiografia , Feminino , Humanos , Masculino , Complicações Pós-Operatórias , Fatores de Risco
17.
Arq. bras. cardiol ; 109(5): 440-447, Nov. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-887971

RESUMO

Abstract Background: Left atrial appendage closure (LAAC) is an effective alternative to oral anticoagulation (OA) for the prevention of stroke in patients with non-valvular atrial fibrillation (NVAF). Objective: To present the immediate results and late outcomes of patients submitted to LAAC and included in the Brazilian Registry of Percutaneous Left Atrial Appendage Closure. Methods: 91 patients with NVAF, high stroke risk (CHA2DS2VASc score = 4.5 ± 1.5) and restrictions to OAC (HAS-BLED score = 3.6 ± 1.0) underwent 92 LAAC procedures using either the Amplatzer cardiac plug or the Watchman device in 11 centers in Brazil, between late 2010 and mid 2016. Results: Ninety-six devices were used (1.04 device/procedure, including an additional non-dedicated device), with a procedural success rate of 97.8%. Associated procedures were performed in 8.7% of the patients. Complete LAAC was obtained in 93.3% of the successful cases. In cases of incomplete closure, no residual leak was larger than 2.5 mm. One patient needed simultaneous implantation of 2 devices. There were 7 periprocedural major (5 pericardial effusions requiring pericardiocentesis, 1 non-dedicated device embolization and 1 coronary air embolism without sequelae) and 4 minor complications. After 128.6 patient-years of follow-up there were 3 deaths unrelated to the procedure, 2 major bleedings (one of them in a patient with an unsuccessful LAAC), thrombus formation over the device in 2 cases (both resolved after resuming OAC for 3 months) and 2 strokes (2.2%). Conclusions: In this multicenter, real world registry, that included patients with NVAF and high thromboembolic and bleeding risks, LAAC effectively prevented stroke and bleeding when compared to the expected rates based on CHA2DS2VASc and HASBLED scores for this population. Complications rate of the procedure was acceptable considering the beginning of the learning curve of most of the involved operators.


Resumo Fundamento: A oclusão percutânea do apêndice atrial esquerdo (OAAE) é uma alternativa eficaz à anticoagulação oral (ACO) para a prevenção de acidente vascular cerebral (AVC) em pacientes com fibrilação atrial não-valvular (FANV). Objetivo: Apresentar os resultados imediatos e o seguimento tardio de pacientes submetidos a OAAE e incluídos no Registro Brasileiro de Oclusão Percutânea do Apêndice Atrial Esquerdo. Métodos: 91 pacientes com FANV, alto risco de AVC (escore CHA2DS2VASc = 4,5 ± 1,5) e restrição à AO (escore HAS-BLED = 3,6 ± 1,0) foram submetidos a 92 procedimentos de OAAE com as próteses Amplatzer Cardiac Plug e Watchman em 11 centros do Brasil, entre o final de 2010 e a metade de 2016. Resultados: Utilizaram-se 96 próteses no total (1,04 próteses/procedimento, incluindo-se o uso de 1 prótese não-dedicada adicional em um dos casos), obtendo-se sucesso em 97,8% dos procedimentos. Realizaram-se procedimentos associados à OAAE em 8,7% dos pacientes. Observou-se oclusão total do AAE em 93,3% dos casos com sucesso, e nos casos de oclusão incompleta, nenhum leak foi > 2,5 mm. Um paciente necessitou do implante simultâneo de 2 próteses. Houve 7 complicações maiores periprocedimento (5 derrames pericárdicos necessitando pericardiocentese, 1 embolização da prótese não-dedicada e 1 embolia aérea coronariana sem sequelas) e 4 menores. No seguimento de 128,6 pacientes-ano, houve 3 óbitos não relacionados ao procedimento, 2 sangramentos maiores (um deles em um dos casos de insucesso da OAAE), formação de trombo sobre a prótese em 2 casos (tratados com sucesso com reinstituição da ACO por 3 meses), e 2 AVCs (2,2%). Conclusões: Neste registro multicêntrico de mundo real, que incluiu pacientes com FANV e alto risco de sangramento e de eventos tromboembólicos, a OAAE foi eficaz na prevenção de AVC e sangramento quando comparada às taxas de AVC previstas pelos escores CHA2DS2VASc e HASBLED para esta população. O índice de complicações do procedimento foi aceitável, considerando se tratar do início da curva de aprendizado da maioria dos operadores envolvidos.


Assuntos
Humanos , Masculino , Feminino , Idoso , Fibrilação Atrial/cirurgia , Apêndice Atrial/cirurgia , Acidente Vascular Cerebral/prevenção & controle , Dispositivo para Oclusão Septal , Fibrilação Atrial/diagnóstico por imagem , Seguimentos , Resultado do Tratamento , Ecocardiografia Transesofagiana , Apêndice Atrial/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia
18.
Arq Bras Cardiol ; 109(5): 440-447, 2017 Nov.
Artigo em Inglês, Português | MEDLINE | ID: mdl-29069203

RESUMO

BACKGROUND: Left atrial appendage closure (LAAC) is an effective alternative to oral anticoagulation (OA) for the prevention of stroke in patients with non-valvular atrial fibrillation (NVAF). OBJECTIVE: To present the immediate results and late outcomes of patients submitted to LAAC and included in the Brazilian Registry of Percutaneous Left Atrial Appendage Closure. METHODS: 91 patients with NVAF, high stroke risk (CHA2DS2VASc score = 4.5 ± 1.5) and restrictions to OAC (HAS-BLED score = 3.6 ± 1.0) underwent 92 LAAC procedures using either the Amplatzer cardiac plug or the Watchman device in 11 centers in Brazil, between late 2010 and mid 2016. RESULTS: Ninety-six devices were used (1.04 device/procedure, including an additional non-dedicated device), with a procedural success rate of 97.8%. Associated procedures were performed in 8.7% of the patients. Complete LAAC was obtained in 93.3% of the successful cases. In cases of incomplete closure, no residual leak was larger than 2.5 mm. One patient needed simultaneous implantation of 2 devices. There were 7 periprocedural major (5 pericardial effusions requiring pericardiocentesis, 1 non-dedicated device embolization and 1 coronary air embolism without sequelae) and 4 minor complications. After 128.6 patient-years of follow-up there were 3 deaths unrelated to the procedure, 2 major bleedings (one of them in a patient with an unsuccessful LAAC), thrombus formation over the device in 2 cases (both resolved after resuming OAC for 3 months) and 2 strokes (2.2%). CONCLUSIONS: In this multicenter, real world registry, that included patients with NVAF and high thromboembolic and bleeding risks, LAAC effectively prevented stroke and bleeding when compared to the expected rates based on CHA2DS2VASc and HASBLED scores for this population. Complications rate of the procedure was acceptable considering the beginning of the learning curve of most of the involved operators.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral/prevenção & controle , Idoso , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Humanos , Masculino , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
19.
Minim Invasive Ther Allied Technol ; 26(1): 60-64, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27658978

RESUMO

Transcatheter aortic valve implantation (TAVI) is a relatively new medical intervention. Research on dedicated TAVI devices is an exciting and dynamic field to be explored by professionals involved in technological innovation. The authors describe in this article the first engineering concept and part of the US Patent of a new valve prosthesis. Divided into two pieces to be separately implanted using a single catheter by means of an innovative technique, this device aims at reducing prosthesis and delivery catheter profile. Miniaturization of the valve and delivery system is probably the best solution to reduce the morbidity and mortality that derive from vascular complications associated with TAVI.


Assuntos
Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/métodos , Humanos , Desenho de Prótese , Fatores de Risco
20.
Rev. bras. cardiol. invasiva ; 23(3): 177-182, jul.-set.2015. ilus, tab
Artigo em Português | LILACS | ID: lil-794194

RESUMO

A fibrilação atrial (FA) aumenta o risco de eventos tromboembólicos por êmbolos origina do sem apêndice atrial esquerdo (AAE). Métodos mecânicos para a oclusão do AAE foram desenvolvidos como alternativa à anticoagulação oral. O objetivo deste trabalho foi apresentar uma experiência inicial com o AMPLATZER® Cardiac Plug. Métodos: Incluímos pacientes com FA permanente ou paroxística, que apresentavam contraindicações ou complicações derivadas da anticoagulação oral. Pacientes com anatomia e medidas do AAE compatíveis com o oclusor, e sem trombos foram selecionados por meio de ecocardiograma transesofágico. Resultados: Foram realizados 14 procedimentos em 13 pacientes (5M:8F), com média de idade de 66,7 anos. Sangramento significativo e acidentes vasculares cerebrais prévios foram encontrados em 69,2% e em 53,8%, respectivamente. A FA era permanente em 84,6% e paroxística no restante da amostra. Os diâmetros médiodo óstio e da zona alvo mediram 23,9 mm e 20,8 mm, respectivamente. AAE bilobulados foram observados em 76,9%. Os procedimentos foram possíveis em todos os casos. Dezesseis dispositivos foram usados em 13 pacientes, numa razão de 1,2:1, e apenas 1 paciente precisou de um segundo dispositivo para oclusão do AAE. O tempo médio de acompanhamento foi de 12,2 meses. Todos os AAE permanecem fechados e sem defeito residual até o momento. Houve apenas um óbito tardio não relacionado ao procedimento. Conclusões: A oclusão do AAE com o dispositivo de AMPLATZER® Cardiac Plug mostrou ser segura e eficaz nesta pequena série de pacientes. Os resultados iniciais são encorajadores e apontam para o fechamento transcateter do AAE como alternativa para a anticoagulação oral em pacientes selecionados...


Atrial fibrillation (AF) increases the risk of thromboembolic events caused by embolioriginating in the left atrial appendage (LAA). Mechanical methods for LAA occlusion have been developed as an alternative to oral anticoagulation. The aim of this study was to present an initial experience with the AMPLATZER® Cardiac Plug. Methods: Patients with permanent or paroxysmal AF and with contraindications or complications of oral anticoagulation were included. Patients with LAA anatomy and measures compatible with the occluder, and without thrombi, were selected through transesophageal echocardiography. Results: A total of 14 procedures were performed in 13 patients (5M:8F), with mean age of 66.7 years. Significant bleeding and previous strokes were found in 69.2% and 53.8%, respectively. AF was permanent in 84.6% and paroxysmal in the remainder. The mean diameters of the ostium and the landing zone were 23.9 mm and 20.8mm, respectively. Bilobulated LAA was observed in 76.9%. Procedures were possible in all cases. Sixteen devices were used in 13 patients, a ratio of 1.2:1, and only one patient required a second device for LAA occlusion. The mean follow-up was 12.2 months. All LAA remain closed, with no residual defect to date. There was only one late death, unrelated to the procedure. Conclusions: LAA occlusion using the AMPLATZER® Cardiac Plug device was shown to be safe and effective in this small series of patients. The initial results are encouraging and indicate the transcatheter closure of the LAA as an alternative to oral anticoagulation therapy in selected patients...


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Acidente Vascular Cerebral , Anticoagulantes/administração & dosagem , Anticoagulantes/uso terapêutico , Fibrilação Atrial/prevenção & controle , Tromboembolia/prevenção & controle , Próteses e Implantes , Angiografia/métodos , Cateteres , Ecocardiografia Transesofagiana/métodos , Fatores de Risco , Heparina/administração & dosagem , Átrios do Coração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...